Brand Name: New Know-How
Model Number: EQL-VA-I1O5000
Place of Origin: China
Leak rate:2 g/a
Gas for Gross Leak Test :dry compressed air or N2
Pressure for Gross Leak Test: 26bar
Pressure for Helium Leak Test:13 bar
Chamber quantity: 1Test chambers
Chambers internal volume
4350(L)×510(H)×2200(W)mm
Products to test in chamber: Each chamber can test 1 pieces of product.
Cycle Time: 1 pcs/ chamber, 15min/pcs, including load& unload time
Working station layout
Gross leak test and helium charging done outside chamber
1. 3 in 1 working station(gross leak test, pre-evacuation vacuum and helium charging)
2. Helium fine leak test in vacuum chamber working station
3. Helium recovery working station
Loading and unloading of Products Manual
Client can define the above specs to design the machine.